162 research outputs found

    Photostatistics Reconstruction via Loop Detector Signatures

    Full text link
    Photon-number resolving detectors are a fundamental building-block of optical quantum information processing protocols. A loop detector, combined with appropriate statistical processing, can be used to convert a binary on/off photon counter into a photon-number-resolving detector. Here we describe the idea of a signature of photon-counts, which may be used to more robustly reconstruct the photon number distribution of a quantum state. The methodology is applied experimentally in a 9-port loop detector operating at a telecommunications wavelength and compared directly to the approach whereby only the number of photon-counts is used to reconstruct the input distribution. The signature approach is shown to be more robust against calibration errors, exhibit reduced statistical uncertainty, and reduced reliance on a-priori assumptions about the input state.Comment: 13 pages, 12 figure

    Experimental reconstruction of photon statistics without photon counting

    Full text link
    Experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams are reported. Our scheme is based on on/off avalanche photodetection assisted by maximum-likelihood estimation and does not involve photon counting. Reconstructions of the distribution for both semiclassical and quantum states of light are reported for single-mode as well as for multimode beams.Comment: Revised version: in press on PRL. 4 pages, 4 fig

    State reconstruction by on/off measurements

    Get PDF
    We demonstrate a state reconstruction technique which provides either the Wigner function or the density matrix of a field mode and requires only avalanche photodetectors, without any phase or amplitude discrimination power. It represents an alternative, of simpler implementation, to quantum homodyne tomography.Comment: 6 pages, 4 figures, revised and enlarged versio

    A Multi-Channel Low-Power System-on-Chip for in vivo NeuralSpike Recording

    Get PDF
    This paper reports a multi-channel neural spike recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 64-channel low-power low-noise analog front-end, a single 8-bit analog-todigital converter (ADC), followed by digital signal compression and transmission units. The 400-MHz transmitter employs a Manchester-Coded Frequency Shift Keying (MC-FSK) modulator with low modulation index. In this way a 1.25-Mbit/s data rate is delivered within a band of about 3 MHz. Compression of the raw data is implemented by detecting the action potentials (APs) and storing 20 samples for each spike waveform. The choice greatly improves data quality and allows single neuron identification. A larger than 10-m transmission range is reached with an overall power consumption of 17.2 mW. This figure translates into a power budget of 269 μW per channel, which is in line with the results in literature but allowing a larger transmission distance and more efficient wireless link bandwidth occupation. The implemented IC was mounted on a small and light printed circuit board to be used during neuroscience experiments with freely-behaving rats. Powered by 2 AAA batteries the system can work continuously for more than 100 hours allowing long-lasting neural spike recordings

    Sub-shot-noise photon-number correlation in mesoscopic twin-beam of light

    Get PDF
    We demonstrate sub-shot-noise photon-number correlations in a (temporal) multimode mesoscopic (103\sim 10^3 detected photons) twin-beam produced by ps-pulsed spontaneous non-degenerate parametric downconversion. We have separately detected the signal and idler distributions of photons collected in twin coherence areas and found that the variance of the photon-count difference goes below the shot-noise limit by 3.25 dB. The number of temporal modes contained in the twin-beam, as well as the size of the twin coherence areas, depends on the pump intensity. Our scheme is based on spontaneous downconversion and thus does not suffer from limitations due to the finite gain of the parametric process. Twin-beams are also used to demonstrate the conditional preparation of a nonclassical (sub-Poissonian) state.Comment: 5 pages, 5 (low-res) figures, to appear on PR

    Measuring the photon distribution by ON/OFF photodectors

    Full text link
    Reconstruction of photon statistics of optical states provide fundamental information on the nature of any optical field and find various relevant applications. Nevertheless, no detector that can reliably discriminate the number of incident photons is available. On the other hand the alternative of reconstructing density matrix by quantum tomography leads to various technical difficulties that are particular severe in the pulsed regime (where mode matching between signal an local oscillator is very challenging). Even if on/off detectors, as usual avalanche PhotoDiodes operating in Geiger mode, seem useless as photocounters, recently it was shown how reconstruction of photon statistics is possible by considering a variable quantum efficiency. Here we present experimental reconstructions of photon number distributions of both continuous-wave and pulsed light beams in a scheme based on on/off avalanche photodetection assisted by maximum-likelihood estimation. Reconstructions of the distribution for both semiclassical and quantum states of light (as single photon, coherent, pseudothermal and multithermal states) are reported for single-mode as well as for multimode beams. The stability and good accuracy obtained in the reconstruction of these states clearly demonstrate the interesting potentialities of this simple technique.Comment: 6 pages, 7 figures, to appear on Laser Physic

    Reconstruction of photon statistics using low performance photon counters

    Get PDF
    The output of a photodetector consists of a current pulse whose charge has the statistical distribution of the actual photon numbers convolved with a Bernoulli distribution. Photodetectors are characterized by a nonunit quantum efficiency, i.e. not all the photons lead to a charge, and by a finite resolution, i.e. a different number of detected photons leads to a discriminable values of the charge only up to a maximum value. We present a detailed comparison, based on Monte Carlo simulated experiments and real data, among the performances of detectors with different upper limits of counting capability. In our scheme the inversion of Bernoulli convolution is performed by maximum-likelihood methods assisted by measurements taken at different quantum efficiencies. We show that detectors that are only able to discriminate between zero, one and more than one detected photons are generally enough to provide a reliable reconstruction of the photon statistics for single-peaked distributions, while detectors with higher resolution limits do not lead to further improvements. In addition, we demonstrate that, for semiclassical states, even on/off detectors are enough to provide a good reconstruction. Finally, we show that a reliable reconstruction of multi-peaked distributions requires either higher quantum efficiency or better capability in discriminating high number of detected photons.Comment: 8 pages, 3 figure

    Direct Drilling of Soybean in a Pensacola Bahiagrass Pasture in the Northwest Region of Rio Grande Do Sul, Brazil

    Get PDF
    The response of methods of soil preparation (M1=conventional tillage, and with notillage using the following herbicides M2=50% Paraquat plus 50% Orizalin; M3=50% Paraquat plus 50% Diquat and M4=Paracol (20% Paraquat plus 20 Diuron)) and row spacing (E1=17 cm, E2=24 cm, E3=51 cm and E4=68 cm) on soybean grain yield direct drilled in an eight-year-old grazed sward of Bahiagrass cv. Pensacola (Paspalum notatum var. saurae Parodi) were studied in southern of Brazil. The results showed that direct drilling of soybean on Pensacola accompanied by desiccant herbicides is a viable agronomic practice. The narrow row spacing is beneficial to this agronomic practice resulting in higher grain yields. The relationship between soybean grain yield and Pensacola dry matter yield was expressed by a negative linear regression. In spite of the damage to the Pensacola caused by herbicides and by soybean competition the sward recovered immediately after the soybean maturation and harvest
    corecore